亚洲综合丁香婷婷六月香_亚洲中文字幕久久精品无码app_亚洲性无码欣赏网_亚洲相片视频在线

Hotline:18857165617 Ms. Yang
Popular: Thermal desorption instrumentation ,Headspace sampler Purge and trapExtraction and distillationAtmospheric preconcentratorGas sampler and dynamic dilutor
News

Company dynamics

Home > News > Company dynamics

Main technical parameters of 95 bit automatic purging and trapping device

source:中儀宇盛   date:2022-04-24 11:25:30   click:
  


The 95 position full-automatic purging and trapping device is a new type of full-automatic purging and trapping device of Beijing Zhongyi Yusheng Technology Co., Ltd. It can be loaded into a 95 position sample bottle once fully loaded, and can be used with all domestic and imported GC and GCMS.

It is suitable for the analysis of volatile organic compounds in liquids and solids, and can also be used for derivative reaction treatment of samples. Liquid sample, sampling to U-tube for purging; For low content solid samples, use 40ml sample bottle to purge directly; For high content solid samples, purge after automatic methanol extraction and dilution.

Types of samples that can be tested: volatile organic compounds in water, wastewater, drinking water, seawater, blood, sediment, slime, soil, cosmetics, textiles, packaging, food, spices, etc.

Main technical parameters

1. Temperature control range of sample tube:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

2. Temperature control range of sample cup:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

3. Injection needle temperature control range:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

4. Temperature control range of GC transmission pipeline:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

5. Temperature control range of valve box:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

6. Temperature control range of U-shaped purging pipe:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

7. Temperature control range of water separator:

5 ℃ to 200 ℃ above room temperature, set in increments of 1 ℃;

8. Temperature control range of pure cleaning water:

5 ℃ to 90 ℃ above room temperature, set in increments of 1 ℃;

9. Trap temperature control range:

150 ℃ to 80 ℃, set in increments of 1 ℃;

10. Trap heating rate:

>2000 ℃ / min, no more than 5% internal overshoot (at 250 ℃);

11. High temperature cooling rate of trap:

Cooling from 250 ℃ to 40 ℃ within 70 seconds;

12. Sample injection accuracy:

RSD < 1% (n = 7), determined by gravimetric method;

13. Selection of sample dilution ratio:

Programmable dilution: 1:100, 1:50, 1:25, 1:10, 1:5, 1:2;

14. Gas flow control range:

5ml / min to 500ml / min;

15. Standard 95 position sample tray (40ml sample bottle) is equipped with sample tray cooling circulating water system to realize low-temperature cooling of sample bottle;


About Us
Company Profile
Appointment interview
corporate culture
Video Center
News
Company dynamics
Common problem
Product
PURGE AND TRAP SERIES
Headspace sampler
Thermal desorption
Gas generator
Consumables and accessories
Contact us
Add:Building 13,Zhongnan High-tech Electronic InformationIndustrial Park,Yanjiao Sanhe Langfang,Hebei,China.
EMAIL:info@bjzyyskj.com.cn
Tel:+86-010-61598028 18857165617 Ms. Yang
Fax:010-61598028-108
WeChat

Scan
Copyright ? 2018 Beijing Zhongyi Yusheng Technology Co., Ltd 京ICP備10046828號-2
霸州市| 东台市| 休宁县| 邓州市| 大田县| 华蓥市| 青冈县| 宁乡县| 长泰县| 香港| 石城县| 平泉县| 高雄县| 思茅市| 邵阳市| 泰顺县| 雅江县| 湖南省| 龙海市| 九寨沟县| 武穴市| 兴城市| 措勤县| 扶余县| 绵阳市| 松原市| 岱山县| 泊头市| 五常市| 万安县| 浠水县| 宜黄县| 高密市| 新蔡县| 宜川县| 双城市| 山西省| 临汾市| 桂阳县| 九寨沟县| 射洪县|